Altium Concord Pro

Public Release Notes for Altium Concord Pro

Created: November 18, 2021 | Updated: January 26, 2022

The following sections list the release notes for publicly released versions of Altium Concord Pro 4.1.

Version 4.1.3

Build: 3 Date: 26 January 2022

19157 Fixed issue with delete from trash being available for user without 'Delete Released' permission.
19198 Fixed issue with non unique HRID generated for new item created in folders with large number of items.

Version 4.1.2

Build: 4 Date: 21 December 2021

Infrastructure & Administration

18870 Remove unused bin\elasticsearch-sql-cli-6.4.2.jar.
18800 Replaced usage of log4j v2.11 libraries with log4j v2.17 libraries.

Version 4.1.1

Build: 6 Date: 22 November 2021

Major Features

13219 Added support for Part Choice propagation from Altium to PLM (as component attributes for all supported PLM, as AML for Arena and Aras).
13422 Added support for Aras PLM integration for component sync.
16977 The MCAD Collaboration service has been enhanced to store and provide information of accepted and rejected changes during MCAD collaboration.

PLM

9348 Improved component synchronization by ensuring that configuration change enforces trigger of full synchronization rather than incremental.
11933 Fixed issue where incremental component sync from PLM to Altium does not pull unreleased Arena items.
12256 Fixed issue where Agile component sync was limited to 10,000 components (for a component type).
12288 Optimized Windchill PartsLink component sync performance.
15340 Fixed issue where component synchronization fails for some non-US regional settings on Windchill server.
16122 Improved support for unit of measure attributes for Windchill classification attributes.

Infrastructure & Administration

16771 Fixed issue where installation hangs in highly secured environment (failed service start and IIS binding creation).
17162 Removed case sensitivity check for user name when logging.
17165 Fixed issue where "Mechatronic 3D Models" folder (required for ECAD MCAD collaboration) was not created during "installation without sample data".
17420 Fixed issue where backup tool fails in specific Windows OS/Updates.

Projects

14560 Fixed issue within Project History where commit date/timestamps were incorrectly presented for some OS regional settings on server machine.
17098 Fixed issue where action buttons in the Project view of the Explorer panel do not work.
17284 Added additional options for MCAD component model naming during ECAD to MCAD Collaboration.
Found an issue with this document? Highlight the area, then use Ctrl+Enter to report it.

Contact Us

Contact our corporate or local offices directly.

We're sorry to hear the article wasn't helpful to you.
Could you take a moment to tell us why?
200 characters remaining
You are reporting an issue with the following selected text
and/or image within the active document: